Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Braz. j. med. biol. res ; 48(7): 644-649, 07/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-751345

RESUMO

Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.


Assuntos
Adulto , Humanos , Masculino , Citocinas/sangue , Infecções por HIV/sangue , Linfoma Relacionado a AIDS/sangue , Linfoma de Células B/sangue , Linfoma de Células B/virologia , Biomarcadores Tumorais/sangue , Bissexualidade , Estudos de Casos e Controles , Infecções por HIV/imunologia , Homossexualidade , Inflamação/sangue , Inflamação/imunologia , Inflamação/virologia , Ativação Linfocitária , Linfoma Relacionado a AIDS/imunologia , Linfoma de Células B/imunologia , Análise Multivariada
2.
Braz J Med Biol Res ; 48(7): 644-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26017344

RESUMO

Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Prótese de Quadril , Neoplasias da Próstata/radioterapia , Doses de Radiação , Adulto , Calibragem , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Humanos , Masculino , Modelos Anatômicos , Imagens de Fantasmas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...